Match Types
The DigiView trigger configuration supports multiple types of Match conditions. The available match types depend on your model of analyzer.Model DV1-100 has 2 standard match types; Pattern and Edges.
Models DV3100 and DV3400 have a total of 8 configurable match circuits and each can be set to one of 9 different match types. All Match Types (except Pattern and Edges) include a duration specifier.
Available Match Types:
- Pattern
- Edges
- Stable
- Equal
- Not Equal
- Greater Than
- Greater Than or Equal
- Less Than
- Less Than or Equal
Match Editor Examples:
Pattern Match Editor - The level trigger is a pattern match detector. You can configure it to match any combination of 0,1 or don't cares across all 18 (or 36) channels.
Stable Match Editor- The Stable Match type is only available on DigiView Models DV3100 and DV3400. All '-' entries for a channel means "don't care". The Stable Match type also has a duration option. Set the duration to "0" to match immediately.