Analyzer Options |
|
|
Each model of DigiView has a different set of options that can be adjusted directly from the software. These options are shown summarized below.
Model DV3100 Hardware Options
Buffer Size - Adjust the amount of capture buffer (1% - 100%) to use in the Hardware.
Prefill - Adjust the amount of buffer to use for data captured before the trigger event. If no trigger event occurs, the analyzer will continuously refresh this portion of the buffer with the most recent data. When the trigger event occurs, the remaining portion of the buffer will be filled with post-trigger data. The behavior of the prefill (or pre-trigger) portion of the buffer can be modified by the Enforce Prefill option.
Enforce Prefill - Select this option to force the analyzer to fill the buffer to the Prefill setting before looking for a trigger condition. If you do not need the full prefill amount before the trigger condition occurs, then uncheck this option to allow early detection of the trigger.
Channel Monitor - This area displays the channel / color relationship and each channels relative activity.
Trigger Threshold - Select the trigger threshold for the group of 18 Channels (9 channels per cable). The selection can be made by highlighting one of the pre-defined values or use the slider beneath these values to select a custom value. The valid range for the threshold on model DV3100 is 0.5V to 2.8V.
Model DV3200 Hardware Options
Buffer Size - Adjust the amount of capture buffer (1% - 100%) to use in the Hardware.
Prefill - Adjust the amount of buffer to use for data captured before the trigger event. If no trigger event occurs, the analyzer will continuously refresh this portion of the buffer with the most recent data. When the trigger event occurs, the remaining portion of the buffer will be filled with post-trigger data. The behavior of the prefill (or pre-trigger) portion of the buffer can be modified by the Enforce Prefill option.
Enforce Prefill - Select this option to force the analyzer to fill the buffer to the Prefill setting before looking for a trigger condition. If you do not need the full prefill amount before the trigger condition occurs, then uncheck this option to allow early detection of the trigger.
Channel Monitor - This area displays the channel / color relationship and each channels relative activity.
Trigger Threshold - Select the trigger threshold for the group of 18 Channels (9 channels per cable). The selection can be made by highlighting one of the pre-defined values or use the slider beneath these values to select a custom value. The valid range for the threshold on model DV3200 is 0.5V to 2.8V.
Model DV3400 Hardware Options
Sample Mode - Select the sample rate and channel mode.
Buffer Size - Adjust the amount of capture buffer (1% - 100%) to use in the Hardware.
Prefill - Adjust the amount of buffer to use for data captured before the trigger event. If no trigger event occurs, the analyzer will continuously refresh this portion of the buffer with the most recent data. When the trigger event occurs, the remaining portion of the buffer will be filled with post-trigger data. The behavior of the prefill (or pre-trigger) portion of the buffer can be modified by the Enforce Prefill option.
Enforce Prefill - Select this option to force the analyzer to fill the buffer to the Prefill setting before looking for a trigger condition. If you do not need the full prefill amount before the trigger condition occurs, then uncheck this option to allow early detection of the trigger.
Channel Monitor - This area displays the channel / color relationship and each channels relative activity.
Trigger Thresholds - Select the trigger threshold for each group of 18 Channels (18 channel models will only display 1 threshold setting). The selection can be made by highlighting one of the pre-defined values or use the slider beneath these values to select a custom value. The valid range for each threshold on model DV3400 is -6V to +6V.
|